Posts Tagged ‘launch’

New IONICON Extended Volatility Range (EVR) PTR-MS

Ultra-Fast Time Response Even for IVOCs & SVOCs

Real-Time Ultra-Sensitive trace VOC analyzers from IONICON are known for their response times in fractions of a second and hence are often used to follow rapidly changing processes and VOC signals. However, some substances are known to show a slower instrumental response because of unwanted surface interactions. These substances are either highly polar or have a reduced volatility and are typically classified as „sticky“ compounds.

IONICON’s new EVR PTR-MS: ultra-fast response times for IVOCs & SVOCs

With IONICON’s new Extended Volatility Range (EVR) setup we minimize unwanted surface interactions and still preserve all the advantages of our fully pressure controlled inlet system. This extends our sub-second response from VOCs to a wide range of compounds in the intermediate-volatility range (IVOCs, e.g. 2-tridecanone and vanillin) and even reduces the response of semi-volatile species (SVOC) like cis-pinonic acid to single-digit seconds. (more…)

CHARON Real-Time Aerosol Inlet System for PTR-TOFMS

Direct Sampling and Analysis of Atmospheric Particulate Organic Matter

An international team of researchers from the University of Innsbruck (Austria), the IRCELYON in Lyon (France) and the University of Oslo (Norway) recently studied the application of the new CHARON Particle Inlet to directly sample and analyze the chemical composition of atmospheric sub-µm particulate organic matter (POM) by PTR-TOFMS.

CHARON PTR-TOF 6000 X2 with two inlets in parallel for real-time VOC and particle analysis

By conducting laboratory based measurements of pure aerosolized substances the team could demonstrate the quantitative response of CHARON PTR-TOFMS to a range of typical POM substances down to single-digit ng m-3 mass concentrations. This quantitative response combined with the low selectivity of PTR-MS led to a good agreement in the detection of total urban POM in comparison with other state-of-the-art aerosol instrumentation.  (more…)

Launching the revolutionary PTR-TOF 6000 X2 trace VOC analyzer

Our next generation high-end PTR-TOFMS for real-time VOC monitoring

We proudly present our new premium PTR-TOF trace VOC analyzer. The PTR-TOF 6000 X2 outperforms all preceding systems and true to our mission as market leaders, it features utmost resolution, sensitivity and lowest real-time detection limit, in a robust, transportable platform that is smaller, lighter and even more affordable than our former flagship product. This results in an impressing mass resolution of over 6000 m/Δm and a sensitivity more than 1000 cps/ppbv with a low detection limit of below 1 pptv.

New PTR-TOF 6000 X2: incl. hexapole ION-GUIDE & ION-BOOSTER funnel

The PTR-TOF 6000 X2 is the first instrument in IONICON’s portfolio based on the new high-resolution release of the “ioniTOF” platform and our PTR technology in combination with the new “X2” features. X2 comprises the latest generation of performance tools incl. the ION-BOOSTER funnel as well as the hexapole ION-GUIDE for the ultimate PTR-TOFMS experience.

(more…)

The new PTR-TOF 4000 trace VOC analyzer: no compromises.

Discover the world’s smallest, commercial high-resolution PTR-TOFMS

You might know that our PTR-TOF 1000 is the smallest and lightest commercial PTR-TOF trace VOC analyzer available. It’s also a huge success for us with over 30 instruments sold since 2014.
You might wonder if we can do even better than this?

IONICON PTR-TOF 4000 trace VOC analyzer

PTR-TOF 4000 trace VOC analyzer

For the first time we combine high-sensitivity with a high mass resolving power in a small and lightweight PTR-TOFMS.

The PTR-TOF 4000 features our new hexapole ION-GUIDE technology and a novel high-resolution TOF. (more…)

Real-time PTR-MS meets autosampler – high throughput VOC analysis

IONICON autosampler for automated head-space analysis with PTR-MS

The real-time capability of a PTR-MS gas analyzer is typically utilized to continuously monitor trace VOC concentrations – but not only. Some users appreciate the enormous speed of a PTR-MS to rapidly analyze discrete samples in seconds, where a manual sample provision can be the bottleneck.

IONICON Autosampler for PTR-MS

This has become greatly facilitated with the new IONICON autosampler for PTR-MS. Analyzing hundreds of sample vials in an automated manner not only provides high data quality but also enables an ultra-high throughput, drastically reducing processing cost for larger batches of samples.

(more…)

New PTR-TOF 1000 ultra launched at Pittcon 2016

Up to 10x increased sensitivity with the new ION-BOOSTER technology.

Our real-time VOC analyzers are known for their exceptional sensitivity. A higher sensitivity not only improves the limit of detection but also allows for a higher measurement frequency at a given signal-to-noise ratio. For real-time VOC analyzers this can have a beneficial implication when investigating highly dynamic processes such as e.g. flux measurements.

New PTR-TOF 1000 ultra with ION-BOOSTER technology.

New PTR-TOF 1000 ultra with ION-BOOSTER technology.

Once again we’re raising the bar: the popular PTR-TOF 1000 instrument, our smallest and most affordable PTR-TOF trace gas analyzer, is now ultra-sensitive.

(more…)

Launching our new ultra-sensitive PTR-QiTOF trace VOC analyzer

Welcome to the future: 25x more sensitive, we proudly present our new flagship PTR-TOFMS instrument: the IONICON PTR-QiTOF.

PTR_QiTOF_webFeaturing a Quadrupole ion guide (Qi), the PTR-QiTOF achieves a performance, no other commercial PTR-TOFMS system has ever been able to demonstrate before.

Expect up to 25x more sensitivity, one order of magnitude lower detection limit and 20% higher mass resolution than the world’s current bestselling and up to now also best-performing PTR-TOFMS instrument – our PTR-TOF 8000.

(more…)