Extreme Performance now also for the PTR-TOF 4000 thanks to X2

Up to 10,000 cps/ppbv with the most versatile high-resolution PTR-TOF

After announcing a new industry benchmark in PTR-MS sensitivity for the PTR-TOF 1000 ultra just weeks ago, today it’s time to shine a spotlight on the PTR-TOF 4000 and its new X2 performance option.

(more…)

PTR-TOF 1000 ULTRA – 2020 Performance Boost and new X2 Option

The “ULTRA” and “X2” effects push instrument sensitivity beyond 20,000

2020 starts with a considerable performance upgrade of the PTR-TOF 1000 ultra. New and improved hardware components increase the instrument’s sensitivity dramatically. Moreover, the PTR-TOF 1000 series now also features a higher mass resolution of > 2,000.

The PTR-TOF 1000 ultra was initially launched in 2016 and with its ION-BOOSTER funnel a considerably more performing instrument than the entry-level PTR-TOF 1000. Now our engineers have revised the ION-BOOSTER and new PTR-TOF 1000 ultra instruments come with 3x higher sensitivity of around 1,500-3,000 cps/ppbv as the new standard configuration. But that’s not the end of the story… (more…)

New PTR-TOF 6000 X2 2019 Edition: More Performance – Reliable Results

Up to 3x increased sensitivity, a better LoD and 10% higher resolution

The IONICON PTR-TOF success story continues also in 2019 and starts with a performance upgrade for our PTR-TOF series. Continuous investments in R&D lead to a series of improvements of our hexapole Ion-Guide technology as well as the implementation of new RF-electronics catering to the high-performance ion-funnel and ion-guide set-up which we use at the PTR-TOF 6000 X2 (more…)

PTR-MS now with Patented Ion-Chemistry Quality and TRU-E/N

The proprietary TRU-E/N™ method for utmost quantification accuracy

Founded by the inventors of Proton-Transfer-Reaction – Mass Spectrometry more than 20 years ago, IONICON has always been renowned for absolutely precise control of the ion chemistry during chemical ionization.

ION-BOOSTER funnel and hexapole ION-GUIDE with TRU-E/N

For IONICON this fact is still true even after the introduction of Radio Frequency (RF) components for focusing and transferring the ions from the reaction region into the mass analyzer.

Several manufacturers of CIMS instruments are trying to boost the sensitivities to the high spheres in which IONICON’s PTR-MS instruments perform. However, this comes at an extremely high cost: control over the ion-chemistry is lost. Undefined fragmentation of analytes renders a comparison of results with values published in the ample PTR-MS literature and, most importantly, accurate quantification impossible. As the reduced electric field strength (E/N) in the reaction region cannot be calculated any more as soon as RF devices are implemented, no E/N values can be stated upon publishing of measurements*, which seriously limits the reproducibility of results. (more…)

Launching the revolutionary PTR-TOF 6000 X2 trace VOC analyzer

Our next generation high-end PTR-TOFMS for real-time VOC monitoring

We proudly present our new premium PTR-TOF trace VOC analyzer. The PTR-TOF 6000 X2 outperforms all preceding systems and true to our mission as market leaders, it features utmost resolution, sensitivity and lowest real-time detection limit, in a robust, transportable platform that is smaller, lighter and even more affordable than our former flagship product. This results in an impressing mass resolution of over 6000 m/Δm and a sensitivity more than 1000 cps/ppbv with a low detection limit of below 1 pptv.

New PTR-TOF 6000 X2: incl. hexapole ION-GUIDE & ION-BOOSTER funnel

The PTR-TOF 6000 X2 is the first instrument in IONICON’s portfolio based on the new high-resolution release of the “ioniTOF” platform and our PTR technology in combination with the new “X2” features. X2 comprises the latest generation of performance tools incl. the ION-BOOSTER funnel as well as the hexapole ION-GUIDE for the ultimate PTR-TOFMS experience.

(more…)

The new PTR-TOF 4000 trace VOC analyzer: no compromises.

Discover the world’s smallest, commercial high-resolution PTR-TOFMS

You might know that our PTR-TOF 1000 is the smallest and lightest commercial PTR-TOF trace VOC analyzer available. It’s also a huge success for us with over 30 instruments sold since 2014.
You might wonder if we can do even better than this?

IONICON PTR-TOF 4000 trace VOC analyzer

PTR-TOF 4000 trace VOC analyzer

For the first time we combine high-sensitivity with a high mass resolving power in a small and lightweight PTR-TOFMS.

The PTR-TOF 4000 features our new hexapole ION-GUIDE technology and a novel high-resolution TOF. (more…)